BookRags.com Literature Guides Literature
Guides
Criticism & Essays Criticism &
Essays
Questions & Answers Questions &
Answers
Lesson Plans Lesson
Plans
My Bibliography Periodic Table U.S. Presidents Shakespeare Sonnet Shake-Up
Research Anything:        
History | Encyclopedias | Films | News | Create a Bibliography | More... Login | Register | Help
Not What You Meant?  There are 16 definitions for NPG.  Also try: NPR.

Unibus

Print-Friendly
About 2 pages (458 words)

Bookmark and Share Know this topic well? Help others and get FREE products!

The Unibus was the earliest of several bus technologies used with PDP-11 and early VAX systems manufactured by the Digital Equipment Corporation of Maynard, Massachusetts. The Unibus was composed of 72 wires (2 connectors x 36 lines per connector). When not counting the power and ground lines, it is usually referred to as a 56 line bus. It could exist within a backplane or on a cable. Up to 20 nodes (devices) could be connected to a single Unibus segment; additional segments could be connected via a bus repeater. The bus was completely asynchronous, allowing a mixture of fast and slow devices. It allowed the overlapping of arbitration (selection of the next bus master) while the current bus master was still performing data transfers. The 18 address lines allowed the addressing of a maximum of 256 kB. Typically, the top 8 kB was reserved for the registers of the memory mapped IO devices used in the PDP-11 architecture. The design deliberately minimized the amount of redundant logic required in the system. For example, a system always contained more slave devices than master devices so most of the fancy logic required to implement asynchronous data transfers was forced into the relatively few master devices. For interrupts, only the interrupt-fielding processor needed to contain the complicated timing logic. The end result was that most I/O controllers could be implemented with very simple logic and most of the critical logic was implemented as a custom MSI IC.

18 A00-A17 - Address Lines
16 D00-D15 - Data Lines
 4 BR4-BR7 - Bus (Interrupt) Requests at priorities 4 (lowest) through 7 (highest)
 4 BG4-BG7 - Bus (Interrupt) Grants at priorities 4 (lowest) through 7 (highest)
 1 NPR     - Non Processor (DMA) Request
 1 NPG     - Non Processor (DMA) Grant
 1 ACLO    - AC Low
 1 DCLO    - DC Low
 1 MSYNC   - Master Sync
 1 SSYNC   - Slave Sync
 1 BBSY    - Bus Busy
 1 SACK    - Selection Acknowledge
 1 INIT    - Bus Init
 1 INTR    - Interrupt Request
 1 PA      - Parity control
 1 PB      - Parity control
 2 C0-C1   - Cyce Control Lines:
 2 +5v     - Power Lines (not counted as part of the 56)
14 Gnd     - Ground Lines (not counted as part of the 56)

The two control lines (C0 and C1) allowed the selection of four different data transfer cycles:

  • DATI (Data In, a read)
  • DATIP (Data In/Pause, the first portion of a Read-Modify-Write operation. A DATO or DATOB operation completes this.)
  • DATO (Data Out, a word write)
  • DATOB (Data Out/Byte, a byte write)
  • During an interrupt cycle, a fifth style of transfer was automatically invoked to convey an interrupt vector from the interrupting device to the interrupt-fielding processor.

View More Summaries on Unibus
 
Ask any question on Unibus and get it answered FAST!
Answer questions in BookRags Q&A and earn points toward
discounted or even FREE Study Guides and other BookRags products!
Learn more about BookRags Q&A
Copyrights
Unibus from Wíkipedia. ©2006 by Wíkipedia. Licensed under the GNU Free Documentation License. View a list of authors or edit this article.

Article Navigation
Join BookRagslearn moreJoin BookRags




About BookRags | Customer Service | Report an Error | Terms of Use | Privacy Policy